You are using beta.rapidonline.com. For the live site go to rapidonline.com

Chauvin Arnoux F200 Series Current Clamps

<p>The <STRONG>Chauvin Arnoux F200 clamp multimeters </STRONG>offer excellent safety as they are rated to CAT IV 600V plus dust protection to IP54 ensuring that safety is maintained over time. These meters are designed to be easy to use when wearing gloves and they adhere to a 1 switch one function scheme, they are also robust, having been tested for drops up to 2 metres. The F200s measure AC current, AC/DC voltage, frequency, resistance, and continuity and has max./min. and inrush functions. Additional measurement types are available such as power factor, mixed AC + DC, harmonic distortion and more.</p>
  • Max. cable diameter 34mm
  • 4 digit LCD
  • Automatic DC/AC detection
  • L x W x H 222 x 78 x 42mm
  • Weighs 340g
Description Image Product Buy Qty Pricing (Ex VAT)
Chauvin Arnoux P01.1209.21 F201 Current Clamp
Chauvin Arnoux P01.1209.21 F201 Current Clamp
Standard range
Order code: 54-7243
MPN: P01120921

Available to back orderBack-order availability date - 09/07/2025
1+ £215.59
Price per unit {{ IncVat ? 'Inc' : 'Ex' }} VAT
Chauvin Arnoux P01.1209.23 F203 Current Clamp
Chauvin Arnoux P01.1209.23 F203 Current Clamp
Standard range
Order code: 54-7244
MPN: P01120923

1 in stock, despatched same dayAdditional quantity lead time 2 days
1+ £235.74
Price per unit {{ IncVat ? 'Inc' : 'Ex' }} VAT
Chauvin Arnoux P01.1209.25 F205 Current Clamp
Chauvin Arnoux P01.1209.25 F205 Current Clamp
Standard range
Order code: 54-7245
MPN: P01120925

1 in stock, despatched same dayAdditional quantity lead time 2 days
1+ £299.13
Price per unit {{ IncVat ? 'Inc' : 'Ex' }} VAT
Order code 54-724354-724454-7245
Mftrs. part no. F201 F203 F205
Display resolution 5999 5999 5999
Display backlighting y y
Acquisition method TRMS TRMS TRMS
Automatic AC/DC detection y y y
Current AC y y y
Current DC y y
Current AC+DC y
Voltage AC y y y
Voltage DC y y y
Voltage AC+DC y
Frequency y y y
Resistance/audible continuity y y y
Temperature (°C / °F) y y
Adapter function y
2-wire phase rotation y
W, var, VA, PF y
THDf / THDr y
Min. / max. y y y
Peak+ / peak- y
True Inrush y y y
∆REL y y