Q. Hello does this mean that you can draw 1A per secondary ouput, or is it 1A total output using both secondaries. I intend to have 2 seperate outputs.
A. Hi Arif, Thanks for your enquiry. This would be 1 amp maximum using both windings .
General purpose chassis mounting mains transformer, 6VA 0-6V, 0-6V with mounting clamp connection. The transformer has a double section fully shrouded bobbin construction with impregnated varnish coating.
| Type | Chassis |
|---|---|
| Primary Voltages | 2 x 120V |
| Secondary Voltages | 2 x 6V |
| Power Rating | 6VA |
| Height | 37mm |
| Length | 45mm |
| Width | 36mm |
| Weight | 0.17kg |
Q. Hello does this mean that you can draw 1A per secondary ouput, or is it 1A total output using both secondaries. I intend to have 2 seperate outputs.
A. Hi Arif, Thanks for your enquiry. This would be 1 amp maximum using both windings .
Q. As this transformer has a maximum power output of 6VA, does this mean that the maximum current output is 1 amp?
A. Hi Steve Thanks for your question. Yes the maximum that can be drawn is 1 amp continuous.